C01902 | diagnostics x70: max. baud rate, C01903 | diagnostics x70: change baud rate, C01905 | diagnostics x70: current baud rate – Lenze E84DSxxx User Manual
Page 632: C01770, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C01765
632
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01765
C01770
C01902
C01903
C01905
Parameter | Name:
C01765 | Service code - difference threshold UG
Data type: UNSIGNED_16
Index: 22810
d
= 591A
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C01770 | Filter time - earth-fault detect. is running
Data type: UNSIGNED_8
Index: 22805
d
= 5915
h
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
250 2 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01902 | Diagnostics X70: Max. baud rate
Data type: UNSIGNED_16
Index: 22673
d
= 5891
h
Maximally permissible baud rate in the standard device after determination of the baud rate at the diagnostic
interface X70
Selection list
(Lenze setting printed in bold)
192 19.200 Bd
384 38.400 Bd
576 57.600 Bd
750 75.000 Bd
1152 115.200 Bd
1500 150.000 Bd
2500 250.000 Bd
3750 375.000 Bd
7500 750.000 Bd
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01903 | Diagnostics X70: Change baud rate
Data type: UNSIGNED_8
Index: 22672
d
= 5890
h
New baud rate determination at the diagnostic interface X70
Selection list
(Lenze setting printed in bold)
0 Ignore changes
1 Negotiate baud rate
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01905 | Diagnostics X70: Current baud rate
Data type: UNSIGNED_32
Index: 22670
d
= 588E
h
Current baud rate at the diagnostic interface X70
Display range
(min. value | unit | max. value)
0
Bd
3000000
Read access Write access CINH PLC STOP No transfer COM MOT