Ot1: maximum torque reached [xx.0123.00001, Oc7: motor overcurrent [xx.0123.00007, Ou: dc bus overvoltage [xx.0123.00014 – Lenze E84DSxxx User Manual

Page 357: Lu: dc bus undervoltage [xx.0123.00015, Message, Lu: undervoltage in the dc bus, Ot1: maximum torque reached, Error m, Lu: dc bus undervoltage, Xx.0123.00015

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

357

9

Diagnostics & error management

9.10

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

OT1: Maximum torque reached [xx.0123.00001]

OC7: Motor overcurrent [xx.0123.00007]

OU: DC bus overvoltage [xx.0123.00014]

LU: DC bus undervoltage [xx.0123.00015]

Response (Lenze setting printed in bold)

Setting:

C00608

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device indicates that the maximally possible torque

at the motor shaft has been reached.

•

C00057

displays the current torque.

Reduce motor load.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Maximum current monitoring has tripped.

Check and, if required, correct dimensioning of the load

with regard to the installed device power.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has detected an overvoltage in the DC bus. To

protect the device hardware, the inverter control is

switched off.

• Depending on the configuration of the auto-start lock

function, set

C00142

so that, when this error is

tripped, the controller only restarts after the

controller inhibit has been switched.

• If this error message remains active longer than the

time set in

C00601

, a "Fault" is tripped.

• Reduce load in generator mode.

• Use a brake resistor.

• Use a regenerative power supply unit.

• Establish a DC-bus connection.

Response (Lenze setting printed in bold)

Setting:

C00600/1

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device has detected a DC bus undervoltage. The

inverter control is switched off because the drive

properties of the motor control cannot be provided

anymore due to the DC bus undervoltage.

• Depending on the configuration of the auto-start lock

function, set

C00142

so that, when this error is

tripped, the controller only restarts after the

controller inhibit has been switched.

• Switch on mains supply or ensure sufficient supply via

DC bus.

• Adjust setting in

C00142

if required.