C01089 | ls_writeparamlist: writevalue_4, C01090 | ls_parreadwrite 1-3: index, C01091 | ls_parreadwrite 1-3: cycletime – Lenze E84DSxxx User Manual
Page 626: E set 4, C01089/1 ... n, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C01089
626
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01089
C01090
C01091
Parameter | Name:
C01089 | LS_WriteParamList: WriteValue_4
Data type: INTEGER_32
Index: 23486
d
= 5BBE
h
: Parameter values - value set 4
Setting range
(min. value | unit | max. value)
-2147483647
2147483647
Subcodes
Lenze setting
Info
C01089/1
0
Parameter values - value set 4
• Parameter values for the parameters defined in
/1 ... 32.
C01089/...
C01089/32
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01090 | LS_ParReadWrite 1-3: Index
Data type: INTEGER_32
Index: 23485
d
= 5BBD
h
From version 06.00.00
Parameter to be read or written.
• Format: <code number>,<subcode number>
• For a setting of "0,000", inputs wParIndex and wParSubindex are effective for addressing purposes instead.
Setting range
(min. value | unit | max. value)
0.000
16000.000
Subcodes
Lenze setting
Info
C01090/1
0.000
: Index
C01090/2
0.000
: Index
C01090/3
0.000
: Index
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C01091 | LS_ParReadWrite 1-3: CycleTime
Data type: UNSIGNED_16
Index: 23484
d
= 5BBC
h
Time interval for cyclic reading/writing
Selection list
0 0 (by Execute)
20 20 ms
50 50 ms
100 100 ms
200 200 ms
500 500 ms
1000 1000 ms
2000 2000 ms
5000 5000 ms
10000 10000 ms
Subcodes
Lenze setting
Info
C01091/1
0: 0 (by Execute)
: Cycle time
C01091/2
0: 0 (by Execute)
: Cycle time
C01091/3
0: 0 (by Execute)
: Cycle time
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1