C00364 | can messageerror, C00366 | number of can sdo channels, T in – Lenze E84DSxxx User Manual

Page 537: C00366, 15 parameter reference

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

537

15

Parameter reference

15.2

Parameter list | C00364

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00364

C00366

Parameter | Name:

C00364 | CAN MessageError

Data type: UNSIGNED_8

Index: 24211

d

= 5E93

h

"CAN on board" system bus

Selection list

(read only)

0 No Error
1 StuffError
2 FormError
3 AckError
4 Bit1Error
5 Bit0Error
6 CRCError
7 Reserved

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00366 | Number of CAN SDO channels

Data type: UNSIGNED_8

Index: 24209

d

= 5E91

h

Change in function from version 02.02.00

Selection of the number of active parameter data channels

Up to and including version 02.01.00

, parameter data channels 1 and 2 are activated in the Lenze setting.

From version 02.02.00

, only parameter data channel 1 is activated according to CANopen in the Lenze setting. To

activate both parameter data channels according to the previous behaviour, select "2 SDO Lenze".

"CAN on board" system bus

Selection list

(Lenze setting printed in bold)

0 1 SDO CANOpen
1 2 SDO Lenze

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Advertising