C00364 | can messageerror, C00366 | number of can sdo channels, T in – Lenze E84DSxxx User Manual
Page 537: C00366, 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
537
15
Parameter reference
15.2
Parameter list | C00364
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00364
C00366
Parameter | Name:
C00364 | CAN MessageError
Data type: UNSIGNED_8
Index: 24211
d
= 5E93
h
Selection list
(read only)
0 No Error
1 StuffError
2 FormError
3 AckError
4 Bit1Error
5 Bit0Error
6 CRCError
7 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00366 | Number of CAN SDO channels
Data type: UNSIGNED_8
Index: 24209
d
= 5E91
h
Change in function from version 02.02.00
Selection of the number of active parameter data channels
•
Up to and including version 02.01.00
, parameter data channels 1 and 2 are activated in the Lenze setting.
•
From version 02.02.00
, only parameter data channel 1 is activated according to CANopen in the Lenze setting. To
activate both parameter data channels according to the previous behaviour, select "2 SDO Lenze".
Selection list
(Lenze setting printed in bold)
0 1 SDO CANOpen
1 2 SDO Lenze
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1