C00761 | la_switchpos: digital connection list, C00761/x, 15 parameter reference – Lenze E84DSxxx User Manual
Page 591

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
591
15
Parameter reference
15.2
Parameter list | C00761
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00761
C00760/22
0: Not connected
: wFreeIn1
(input for user signal 1)
C00760/23
0: Not connected
: wFreeIn2
(input for user signal 2)
C00760/24
0: Not connected
: wFreeIn3
(input for user signal 3)
C00760/25
0: Not connected
: wFreeIn4
(input for user signal 4)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00760 | LA_SwitchPos: Analog connection list
Data type: UNSIGNED_16
Index: 23815
d
= 5D07
h
Parameter | Name:
C00761 | LA_SwitchPos: Digital connection list
Data type: UNSIGNED_16
Index: 23814
d
= 5D06
h
Connection parameters for "Switch-off positioning" application: Binary inputs
• Selection of the binary output signals to be connected to the binary input signals
• The selection list contains all binary output signals which can be assigned to the binary inputs mapped by the
subcodes.
Selection list
See
selection list - digital signals
Subcodes
Lenze setting
Info
C00761/1
0: Not connected
: bCInh
(control input for setting controller inhibit)
C00761/2
0: Not connected
: bFailReset
(control input for error acknowledgement)
C00761/3
0: Not connected
: bSetQuickstop
(control input for quick stop request)
C00761/4
0: Not connected
: bSetDCBrake
(control input for DC-injection braking request)
C00761/5
0: Not connected
: bRFG_Stop
(control input for stopping the speed ramp function
generator)
C00761/6
0: Not connected
: bSetSpeedCcw
(control input for change of direction of rotation)
C00761/7
0: Not connected
: bRLQCw
(control input for activation of CW rotation (fail-safe))
C00761/8
0: Not connected
: bRLQCcw
(control input for activation of CCW rotation (fail-safe))
C00761/9
0: Not connected
: bJogCtrlInputSel1
(selection input 1 for binary coded selection of the
switch-off position 1 ... 3)
C00761/10
0: Not connected
: bJogCtrlInputSel2
(selection input 2 for binary coded selection of the
switch-off position 1 ... 3)
C00761/11
0: Not connected
: bJogCtrlRfgIn
(control input for setpoint generator ramp-down)
C00761/12
0: Not connected
: bJogCtrlJog1
(selection input 1 for overriding fixed setpoints (JOG
setpoints) for the main setpoint)
C00761/13
0: Not connected
: bJogCtrlJog2
(selection input 2 for overriding fixed setpoints (JOG
setpoints) for the main setpoint)