C02611
Parameter | Name:
C02611 | MCK: Limitations
Data type: INTEGER_16
Index: 21964
d
= 55CC
h
Speed setpoint limits for the determination of limited validity ranges
Note:
Traversing with setpoints through resulting blocking zones is executed with the ramp set in
Setting range
(min. value | unit | max. value)
0.00
%
199.99
Subcodes
Lenze setting
Info
C02611/1
199.99 %
MCK: Pos. max. speed
• Upper limit of the speed setpoint limitation in
positive direction of rotation.
C02611/2
0.00 %
MCK: Pos. min. speed
• Lower limit of the speed setpoint limitation in
positive direction of rotation.
C02611/3
0.00 %
MCK: Neg. min. speed
• Lower limit of the speed setpoint limitation in
negative direction of rotation.
C02611/4
199.99 %
MCK: Neg. max. speed
• Upper limit of the speed setpoint limitation in
negative direction of rotation.
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100