9diagnostics & error management – Lenze E84DSxxx User Manual
Page 354

9
Diagnostics & error management
9.10
Error messages of the operating system
354
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x190b
6411
Io11: DigOut level
Warning
0xF000
0x1791
6033
LP1: Motor phase failure
No Reaction
0x3000
0x170f
5903
LU: DC bus undervoltage
Trouble
0x3100
0x280d
10253
MCI1: Module missing / incompatible
No Reaction
0x7000
0x1710
5904
OC1: Power section - short circuit
Fault
-
0x2000
0x1711
5905
OC2: Power section - earth fault
Fault
-
0x2000
0x1332
4914
OC5: Ixt overload
Fault
-
0x2000
0x1769
5993
OC6: I2xt motor overload
Warning
0x2000
0x1707
5895
OC7: Motor overcurrent
Fault
-
0x2000
0x171e
5918
OC10: Max. current reached
Fault
-
0x2000
0x1747
5959
OC11: Active clamp operation
Warning
-
0xF000
0x1741
5953
OC12: I2xt overload - brake resistor
Fault
-
0xF000
0x175a
5978
OC13: Max. current for Fch exceeded
Fault
-
0xF000
0x1760
5984
OC14: Direct-axis current controller limitation
No Reaction
0xF000
0x1761
5985
OC15: Cross current controller limitation
No Reaction
0xF000
0x1762
5986
OC16: Torque controller limitation
No Reaction
0xF000
0x171f
5919
OC17: Clamp sets pulse inhibit
No Reaction
0xF000
0x1301
4865
OH1: Heatsink overtemperature
Fault
-
0x4000
0x130f
4879
OH3: Motor temperature (X21) triggered
Fault
0x4000
0x1300
4864
OH4: Heatsink temp. > shutdown temp. -5°C
No Reaction
0x4000
0x1720
5920
OS1: Max. speed limit reached
No Reaction
0x8400
0x1701
5889
OT1: Max. torque reached
No Reaction
0x8300
0x175d
5981
OT2: Speed controller output limited
No Reaction
0xF000
0x170e
5902
OU: Überspannung Zwischenkreis
Trouble
-
0x3100
0x2c01
11265
PS01: No memory module
Warning
-
0x6300
0x2c02
11266
PS02: Invalid par. set
Fault
-
0x6300
0x2c03
11267
PS03: Invalid device par. set
Fault
-
0x6300
0x2c04
11268
PS04: Invalid MCI par. set
Fault
-
0x6300
0x2c07
11271
PS07: Invalid memory module par. set
Fault
-
0x6300
0x2c08
11272
PS08: Invalid device par.
Fault
-
0x6300
0x2c09
11273
PS09: Invalid par. format
Fault
-
0x6300
0x2c0a
11274
PS10: Memory module binding invalid
Fault
-
0x17cd
6093
SD3: Open circuit - feedback system
Fault
0x7300
0x17c8
6088
SD10: Speed limit - feedback system 12
Fault
0x7300
0x0b02
2818
Su02: One mains phase is missing
Warning
0x3000
0x0b03
2819
Su03: Too frequent mains switching
Fault
-
0x3000
0x0b04
2820
Su04: CU Insufficiently Supplied
Warning
-
0x3000
0x0b05
2821
Su05: IO supply overload
Warning
0x3000
-
-
US01: User error 1
No Reaction
0x6200
-
-
US02: User error 2
No Reaction
0x6200
-
-
US03: User error 3
No Reaction
0x6200
-
-
US04: User error 4
No Reaction
0x6200
Error number
Error message
Response
(Lenze setting)
can be set in
CAN Emergency
Error Code
32 bits
16 bits
hex
16 bits
dec