7technology applications – Lenze E84DSxxx User Manual
Page 272

7
Technology applications
7.3
TA "Switch-off positioning"
272
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
MCK basic functions
bBrakeReleaseOut
BOOL
: Trigger signal for the holding brake control switching
element via a digital output
• Use bit 0 in
to activate inverted switching element triggering.
FALSE Apply brake.
TRUE Release brake.
bBrakeReleased
BOOL
: Status signal of the brake control with regard to the release
and application times of the brake
FALSE Brake applied (after the brake application time has expired).
TRUE Brake released (after the brake release time has expired).
GP: GeneralPurpose
The following outputs are interconnected with logic/arithmetic functions on application level for free usage.
nGPAnalogSwitchInOut_a
INT
: Output signal
nGPArithmetikOut_a
INT
: Output signal
nGPMulDivOut_a
INT
: Output signal
bGPDigitalDelayOut
BOOL
: Output signal
bGPLogicOut
BOOL
: Output signal
bGPCompareOut
BOOL
: Output signal
bGPSignalOut1
...
bGPSignalOut4
BOOL
: Output signals
• The signal sources to be output are selected in
.
• A bit coded inversion of the output signals can be parameterised in
nGPSignalOut1_a
...
nGPSignalOut4_a
BOOL
: Output signals
• The signal sources to be output are selected in
.
• Gain and offset for each output signal can be parameterised in
bGPDFlipFlop_Out
BOOL
: Output signal
bGPDFlipFlop_NegOut
BOOL
: Negated output signal
Free outputs
The following outputs can freely be interconnected on the application level.
The signals from the application level can be transferred to the I/O level via these outputs.
bFreeOut1 ... bFreeOut8
BOOL
Free outputs for digital signals
wFreeOut1 ... wFreeOut4
WORD
Free outputs for 16-bit signals
dnFreeOut1_p
dnFreeOut2_p
WORD
Free outputs for 32-bit signals
Identifier
Data type
Value/meaning