C00877 | mci output words, C00890 | mci_inout: inversion, C00890/1 – Lenze E84DSxxx User Manual
Page 616: C00890/3, C00877/1, C00877/2, C00890/2, C00890/4, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00877
616
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00877
C00890
Parameter | Name:
C00877 | MCI output words
Data type: UNSIGNED_16
Index: 23698
d
= 5C92
h
Display of the 16 bit output values of the communication module
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Bit 0 Active
... ...
Bit 15 Active
Subcodes
Info
C00877/1
: wState
C00877/2
: wOut2
C00877/3
: wOut3
C00877/4
: wOut4
C00877/5
: wOut5
C00877/6
: wOut6
C00877/7
: wOut7
C00877/8
: wOut8
C00877/9
: wOut9
C00877/10
: wOut10
C00877/11
: wOut11
C00877/12
: wOut12
C00877/13
: wOut13
C00877/14
: wOut14
C00877/15
: wOut15
C00877/16
: wOut16
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00890 | MCI_InOut: Inversion
Data type: UNSIGNED_16
Index: 23685
d
= 5C85
h
This parameter serves to invert the control/status bits of the MCI port blocks.
Setting range
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 Active
Bit set = inversion active
... ...
Bit 15 Active
Subcodes
Lenze setting
Info
C00890/1
0
Inversion of LP_MciIn.wCtrl
C00890/2
0
Inversion of LP_MciOut.wState
C00890/3
0
Inversion of LP_MciIn.bIn2_B0...15
C00890/4
0
Inversion of LP_MciOut.bOut2_B0...15