C00594 | resp. to control word error, C00597 | resp. to motor phase failure, C00598 | resp. to i/o monitoring – Lenze E84DSxxx User Manual

Page 567: C00597, Will take place, C00598, C00598/1, C00594/2, C00598/3, C00598/4

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

567

15

Parameter reference

15.2

Parameter list | C00594

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00594

C00597

C00598

Parameter | Name:

C00594 | Resp. to control word error

Data type: UNSIGNED_8

Index: 23981

d

= 5DAD

h

Configuration of device control monitoring
Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
5 Warning

Subcodes

Lenze setting

Info

C00594/1

1: Fault

Response if error bit 14 in the CAN control word is set.

C00594/2

1: Fault

Response if error bit 14 in the MCI control word is set.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00597 | Resp. to motor phase failure

Data type: UNSIGNED_8

Index: 23978

d

= 5DAA

h

Response to motor phase failure

• If a phase current does not exceed the threshold set in

C00599

for more than one period, the response set here

will be triggered.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00598 | Resp. to I/O monitoring

Data type: UNSIGNED_8

Index: 23977

d

= 5DA9

h

Configuration of analog input monitoring

Analog terminals

Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
5 Warning

Subcodes

Lenze setting

Info

C00598/1

3: TroubleQuickStop

Response to open circuit at AIN1 if configured as

4 ... 20 mA current loop

C00598/2

0: No Reaction

Reserved

C00598/3

5: Warning

Resp. to digital output level

C00598/4

5: Warning

Resp. to IO supply overload

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1