5motor control (mctrl) – Lenze E84DSxxx User Manual

Page 158

Advertising
background image

5

Motor control (MCTRL)

5.7

Parameterisable additional functions

158

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Explanation of the automatic DC-injection braking function by means of two examples

[5-13] Example 1: Signal characteristic for automatic DC-injection braking of a drive without speed feedback

 Speed setpoint

 Actual speed value of the motor

 Output current of the controller

 Pulse inhibit

 DC-injection braking is active

The motor rotates at a specified

speed. The current adjusts itself to

the load, see .

The DC braking current set in

C00036

is injected.

After the hold time (

C00106

) has

expired, a pulse inhibit is set.

0

1

2

3

4



‚

C0107

C00036

C00019

ƒ