15 parameter reference – Lenze E84DSxxx User Manual
Page 584

15
Parameter reference
15.2
Parameter list | C00700
584
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00700/11
0: Not connected
: nGPArithmetikIn1_a
(input for arithmetic function analog signal 1)
C00700/12
0: Not connected
: nGPArithmetikIn2_a
(input for arithmetic function analog signal 2)
C00700/13
0: Not connected
: nGPMulDivIn_a
(input for analog signal for multiplication/division)
C00700/14
0: Not connected
: nGPCompareIn1_a
(input for comparison operation analog signal 1)
C00700/15
0: Not connected
: nGPCompareIn2_a
(input for comparison operation analog signal 2)
C00700/16
0: Not connected
: nVoltageAdd_a
(input for additive voltage boost)
C00700/17
0: Not connected
: nPIDInfluence_a
(input for influence signal of PID controller correcting
variable)
C00700/18
0: Not connected
: nPIDSetValue_a
(input for PID controller setpoint)
C00700/19
0: Not connected
: nPWMAngleOffset
(input for pulse width modulation phase offset)
C00700/20
0: Not connected
: nBoost_a
(input for additional setpoint for the motor voltage at
speed = 0)
C00700/21
0: Not connected
: wSMCtrl
(interface to optional safety system)
C00700/22
0: Not connected
Reserved
C00700/23
0: Not connected
Reserved
C00700/24
0: Not connected
Reserved
C00700/25
0: Not connected
Reserved
C00700/26
0: Not connected
: wFreeIn1
(input for user signal 1)
C00700/27
0: Not connected
: wFreeIn2
(input for user signal 2)
C00700/28
0: Not connected
: wFreeIn3
(input for user signal 3)
C00700/29
0: Not connected
: wFreeIn4
(input for user signal 4)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00700 | LA_NCtrl: Analog connection list
Data type: UNSIGNED_16
Index: 23875
d
= 5D43
h