39 l_signalmonitor_b, L_signalmonitor_b, 17 function library – Lenze E84DSxxx User Manual
Page 779

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
779
17
Function library
17.1
Function blocks | L_SignalMonitor_b
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.39
L_SignalMonitor_b
This FB outputs four binary signals which can be selected from a list of binary output signals of all
function blocks provided in the device.
• Inversion of the output signals can be set.
Outputs
Parameter
Identifier
Data type
Value/meaning
bOut1
...
bOut4
BOOL
Output signal
FALSE / TRUE
Parameter
Possible settings
Info
...
Selection of the signal sources for
bOut1 ... bOut4
0 Not connected
1000 LA_nCtrl_bDriveReady
1001 LA_nCtrl_bDriveFail
1002 LA_nCtrl_bCInhActive
.. ...
42033 LA_NCtrl_bPIDIOff
Inversion
• Bit set = inversion active
Bit 0
bOut1 inverted
Bit 1
bOut2 inverted
Bit 2
bOut3 inverted
Bit 3
bOut4 inverted
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Reserved
Bit 7
Reserved