C01124
C01138
C01139
Parameter | Name:
C01124 | Sync correction width
Data type: UNSIGNED_8
Index: 23451
d
= 5B9B
h
Correction increment for device synchronisation
• If the cycle times of the synchronisation signal differs and phase-locken loop (PLL) differ from each other, this
setting defines the measure the phase-locking loop is reset with.
• If synchronisation is not reached, select a higher correction constant.
• The optimum setting depends on quartz precision and must be determined empirically if required.
Selection list
(Lenze setting printed in bold)
1 100ns
2 200ns
3 300ns
4 400ns
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01138 | L_Transient 1-4: Function
Data type: UNSIGNED_8
Index: 23437
d
= 5B8D
h
Selection of edge evaluation
Selection list
0 High edge
1 Low edge
2 High and low edge
Subcodes
Lenze setting
Info
C01138/1
0: High edge
: Function
C01138/2
0: High edge
: Function
C01138/3
0: High edge
: Function
C01138/4
0: High edge
: Function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01139 | L_Transient 1-4: Pulse duration
Data type: UNSIGNED_16
Index: 23436
d
= 5B8C
h
Setting range
(min. value | unit | max. value)
0.000
s
60.000
Subcodes
Lenze setting
Info
C01139/1
0.000 s
: Pulse duration
C01139/2
0.000 s
: Pulse duration
C01139/3
0.000 s
: Pulse duration
C01139/4
0.000 s
: Pulse duration
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000