4 process when brake is closed, Process when brake is closed, Process – Lenze E84DSxxx User Manual

Page 318: When brake is closed, 8basic drive functions (mck)

Advertising
background image

8

Basic drive functions (MCK)

8.4

Holding brake control

318

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.4.4

Process when brake is closed

1. The motor is decelerated when the setpoint is reduced by the user (e.g. turn down the

potentiometer, setpoint selection via CAN).

• The motor can also be decelerated by the "Quick stop" function or by "DC-injection braking",

either directly requested by the user or as response to an error.

2. If the speed setpoint and the actual speed have fallen below the lower speed threshold or only

the speed setpoint has fallen below the lower speed threshold and the actual value monitoring

time has expired:

• The bBrkReleaseOut trigger signal for the holding brake switching element is set to FALSE for

closing the brake.

• The bBrkReleased status signal is reset to FALSE.
• The brake application time starts to expire.

3. After the brake application time has expired, the controller is inhibited.

Time diagrams

[8-10] Close holding brake in automatic mode via speed threshold (actual value = setpoint)

 Feedforward control

C02581/1

: Switching threshold

C02581/2

: Hysteresis for release

C02581/3

: Hysteresis for application

Application delay

C02589/1

: Application time

Œ 

bBrkReleaseOut

0

0

bBrkReleased

CINH

t

t

t

t







0

nSpeedSetValue_a_

nSpeedSetValue_a

Œ

Œ Ž

Advertising