C00107 | dcb: hold time, C00114 | dix: polarity, C00107 – Lenze E84DSxxx User Manual
Page 494: C00114, Fter the hold time, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00107
494
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00107
C00114
Parameter | Name:
C00107 | DCB: Hold time
Data type: UNSIGNED_32
Index: 24468
d
= 5F94
h
Maximum hold time of the manual DC injection brake
• A time can be set here after which the DC injection brake is switched off automatically to prevent the motor from
thermal overload.
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
s
999.000 999.000 s
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1000
Parameter | Name:
C00114 | DIx: Polarity
Data type: UNSIGNED_16
Index: 24461
d
= 5F8D
h
Polarity of the digital inputs
• The polarity of each digital input of the device can be inverted via this bit field.
Setting range
(min. hex value | max. hex value)
Lenze setting
0x0000
0xFFFF 0x0000 (decimal: 0)
Value is bit-coded: ( = bit set)
Info
Bit 0 DI1 inverted
Inversion of digital input 1
Bit 1 DI2 inverted
Inversion of digital input 2
Bit 2 DI3 inverted
Inversion of digital input 3
Bit 3 DI4 inverted
Inversion of digital input 4
Bit 4 DI5 inverted
Inversion of digital input 5
Bit 5 DI6 inverted
Inversion of digital input 6
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 RFR inverted
Inversion of digital input RFR (controller enable)
Read access Write access CINH PLC STOP No transfer COM MOT