C01082 | ls_writeparamlist: execute mode, C01083 | ls_writeparamlist: failstate, C01084 | ls_writeparamlist: error line – Lenze E84DSxxx User Manual

Page 624: C01085 | ls_writeparamlist: index, If execute mode, C01082, C01085/1 ... n, C01085/1, C01085/2, C01085/3

Advertising
background image

15

Parameter reference

15.2

Parameter list | C01082

624

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01082

C01083

C01084

C01085

Parameter | Name:

C01082 | LS_WriteParamList: Execute Mode

Data type: UNSIGNED_8

Index: 23493

d

= 5BC5

h

From version 02.00.00

Parameter change-over

: Selection of the activation method

Selection list

(Lenze setting printed in bold)

Info

0 by Execute

The writing of the parameter list is activated by a

FALSE/TRUE edge at the bExecute input.

1 by Input Select

The writing of the parameter list is carried out if a change

is made at the select inputs and if the controller is

initialised.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01083 | LS_WriteParamList: FailState

Data type: UNSIGNED_16

Index: 23492

d

= 5BC4

h

Parameter change-over

: Error status:

• 0 = no error

• 33803 = Invalid data type (e.g. STRING)

• 33804 = limit violation

• 33806 = invalid code

• 33813 = no element of the selection list

• 33815 = writing of the parameter not permitted

• 33816 = writing of the parameter only permitted if controller is inhibited

• 33829 = invalid subcode

• 33865 = no parameter with subcodes

Display range

(min. value | unit | max. value)

0

34000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01084 | LS_WriteParamList: Error line

Data type: UNSIGNED_8

Index: 23491

d

= 5BC3

h

Parameter change-over

: Display of the number of list entry where the error occurred (in connection with the value

set selected via bSelectWriteValue_1 and bSelectWriteValue_2).
Display range

(min. value | unit | max. value)

0

32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01085 | LS_WriteParamList: Index

Data type: INTEGER_32

Index: 23490

d

= 5BC2

h

Parameter change-over

: Parameter for entry 1 ... 32

Setting range

(min. value | unit | max. value)

0.000

16000.000

Subcodes

Lenze setting

Info

C01085/1

0.000

Parameter for entries 1 ... 32

• Format: <code number>.<subcode number>

• Examples: "12.000" = C00012; "26.001" = C00026/1

C01085/...
C01085/32

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000