Ce3: can rpdo3 [xx.0135.00003, Cp04: can rpdo4 [xx.0135.00004, Mci1: module missing/incompatible [xx.0140.00013 – Lenze E84DSxxx User Manual
Page 365: Ps01: no memory module [xx.0144.00001, Ps02: par. set invalid [xx.0144.00002, Warning, Ps01: no, Memory module, Xx.0135.00003, Xx.0135.00004

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
365
9
Diagnostics & error management
9.10
Error messages of the operating system
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
CE3: CAN RPDO3 [xx.0135.00003]
CP04: CAN RPDO4 [xx.0135.00004]
MCI1: Module missing/incompatible [xx.0140.00013]
PS01: No memory module [xx.0144.00001]
PS02: Par. set invalid [xx.0144.00002]
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
: Time monitoring for RPDO3 has been
triggered.
• RPDO3 has not been received within the monitoring
time set in
or was faulty.
• Set correct telegram length for CAN master
(transmitter).
• Eliminate electrical interference (e.g. EMC).
• Adjust monitoring time
or switch off time
monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
: Time monitoring for RPDO4 has been
triggered.
• RPDO4 has not been received within the monitoring
time set in
or was faulty.
• Set correct telegram length for CAN master
(transmitter).
• Eliminate electrical interference (e.g. EMC).
• Adjust monitoring time
or switch off time
monitoring.
Response (Lenze setting printed in bold)
Setting:
( Adjustable response)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The optional communication module has been removed
or there is a connection problem or incompatibility with
the standard device.
• Check connection between the communication
module and standard device.
• Check if the module is plugged in correctly.
• In case of an incompatibility, either the module or the
software of the standard device is out of date. In this
case, please contact Lenze.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
Memory module is either not available or not snapped
into place correctly.
• If a memory module has been provided: Plug the
memory module into the slot of the standard device
intended for this purpose.
• If a memory module has been provided: Check if the
memory module has been plugged-in correctly.
Response (Lenze setting printed in bold)
0: No Reaction 1: Fault 2: Trouble 3: TroubleQuickStop 4: WarningLocked 5: Warning 6: Information
Cause
Remedy
The parameter set saved to the memory module is
invalid because it has not been saved completely.
• This can be due to voltage failure or caused by
removing the memory module while saving the
parameter set.
Ensure voltage supply during the storage process and
that the module remains plugged into the slot.