2 creating an »engineer« project & going online, Creating an »engineer« project & going online, 3commissioning – Lenze E84DSxxx User Manual

Page 48

Advertising
background image

3

Commissioning

3.7

Commissioning of the "Actuating drive speed" technology application

48

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.7.2

Creating an »Engineer« project & going online

The following steps serve to describe a general method for creating a project with the Select

component from catalogue option. For this purpose, individual components (controller, motor, etc.)

are selected from selection lists.

1. Start the »Engineer«.
2. Create a new project with the Start-up wizard and the Select component from catalogue option:

• In the Component step, select the 8400 protec StateLine controller.
• Select the available communication and safety system in the Device modules dialog step.
• In the Application step, select the "Actuating drive speed" application. (The application can

also be selected any time afterwards via the Application parameter tab or

C00005

.)

• In the Other components step, select other components (motor / gearbox) to be added to the

project.

3.

Go online.

• After a connection to the controller has been established, the following status is displayed in

the Status line:

4. If the controller is enabled:

Inhibit

controller.

5.

Transfer parameter set to the device.

• This command serves to overwrite the current parameter settings in the controller by

parameter settings of the »Engineer« project.

You can find detailed information on the general use of the »Engineer« in the online help

which you can call with [F1].

• The chapter "Working with projects" describes, among other things, all options of the

Start-up wizard which are available to create a new »Engineer« project.

Advertising