Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

189

5

Motor control (MCTRL)

5.10

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Response to open circuit

• If the open-circuit monitoring is tripped:

• The error response set in

C00586

is activated (Lenze setting: "Fault").

• The "

SD3: Open circuit - feedback system

" is entered into the Logbook.

• The bMctrlEncoderComFault status output of the

LS_DeviceMonitor

SB is set to TRUE.

• A setting of

C00586

= "0: No Reaction" deactivates the monitoring.