1 password protection, Password protection, 2introduction: parameterising the controller – Lenze E84DSxxx User Manual

Page 34

Advertising
background image

2

Introduction: Parameterising the controller

2.4

Device access protection

34

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.4.1

Password protection

When the password protection is active, only write/read access to the parameters of the user menu

is possible. An option for configuring various protection functions for each individual

communication channel is currently being prepared.

• The following describes how to set/check/delete a password by means of the parameters

relevant for these functions.

From »Engineer« V2.14 onwards

. these functions can also be executed via dialog (menu

command OnlineSet/check/delete password).

Short overview of the relevant parameters for password protection:

Parameter

Info

Lenze setting

C00505/3

Password

• The password may have a maximum length of 16 characters.

• The following characters are permitted for the password:

Small letters (a - z), capital letters (A - Z), digits (0 - 9)

Note:

After the execution of one of the device commands listed below, this

parameter provides the current password status:

OFF No password is set, password protection is not active

(Lenze delivery status).

ON Password is set, password protection is active.

• This status is also displayed if checking/deleting

the password has not been successful due to an

invalid entry.

ok Password is set, password protection is not active.

• The password protection is temporarily

deactivated.

Device commands

Before the following device commands are executed, enter the corresponding password in

C00505/3

.

C00002/31

Set password

Activate the password protection

0: Off / ready

C00002/32

Check password

Temporarily deactivate the password protection

0: Off / ready

C00002/33

Delete password

Deactivate password protection/change password

0: Off / ready

Status displays

C00003

Status of the last device command

-

C00507/1

Password protection - all communication channels

• Bit coded display of the active protective functions:

-

Bit 0 Only access to user menu
Bit 1 Parameter write protection
Bit 2 Parameter read protection

Bit 3 ... 14 Reserved

Bit 16 Memory module binding on

Highlighted in grey = display parameter

Advertising