1 available process data objects, Available process data objects, 10 canopen option – Lenze E84DSxxx User Manual
Page 387

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
387
10
CANopen option
10.8
Process data transfer
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.8.1
Available process data objects
Controllers of the 8400 series have a maximum number of 3 receive PDOs (RPDOs) and 3 transmit
PDOs (TPDOs).
Receive PDOs (RPDOs)
The process data objects transmitted from the system bus to the drive are processed via the
...
port blocks.
• Every port block provides 4 words (2 bytes/word). The data of every first word are provided in a
bit decoded manner (bit 0 ... 15).
• The first word of the
port block is defined as control word wCtrl. The wCtrl control
word does not have a permanent connection to the device control and can be used as required.
The predefined assignment of the wCtrl control word in the
= "30: CAN" control mode
depends on the technology application selected in
:
• TA "Actuating drive speed":
Process data assignment for fieldbus communication
• TA "Abschaltpositionierung":
Process data assignment for fieldbus communication
Transmit PDOs (TPDOs)
The process data transmitted from the drive to the system bus are processed via the
...
port blocks.
• Every port block receives 4 words (2 bytes/word). The data of every first word are transmitted
bit by bit (bit 0 ... 15).
• The first word of the
port block is defined as the wState status word. The wState
status word does not have a permanent connection to the device control and can be used as
required.
• Vordefinierte Belegung siehe
der Antriebsschnittstelle.
Process data object
Version
"BaseLine C"
from version
"StateLine"
RPDO1 | Port block "LP_CanIn1"
RPDO2 | "LP_CanIn2" port block
RPDO3 | "LP_CanIn3" port block
TPDO1 | "LP_CanOut1" port block
TPDO2 | "LP_CanOut2" port block
TPDO3 | "LP_CanOut3" port block