C00246 | l_pctrl_1: nact_a internal, C00247 | l_pctrl_1: acteqset window, C00249 | l_pt1_1: time constant – Lenze E84DSxxx User Manual
Page 523: C00273 | moment of inertia, C00275 | filter setpoint feedforward control, C00275, C00273, Under, Set too, And repe

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
523
15
Parameter reference
15.2
Parameter list | C00246
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00246
C00247
C00249
C00265
C00273
C00275
Parameter | Name:
C00246 | L_PCTRL_1: nAct_a internal
Data type: INTEGER_16
Index: 24329
d
= 5F09
h
FB
: Display of the internal actual value
Display range
(min. value | unit | max. value)
-199.99
%
199.99
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00247 | L_PCTRL_1: ActEqSet window
Data type: INTEGER_16
Index: 24328
d
= 5F08
h
From version 06.00.00
FB
: Window for comparison operation "actual value = setpoint"
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
%
100.00 2.00 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00249 | L_PT1_1: Time constant
Data type: UNSIGNED_16
Index: 24326
d
= 5F06
h
FB
: Time constant Tn
Setting range
(min. value | unit | max. value)
Lenze setting
0
ms
5000 2000 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00265 | SLVC: Tn torque controller
Data type: UNSIGNED_8
Index: 24310
d
= 5EF6
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00273 | Moment of inertia
Data type: UNSIGNED_32
Index: 24302
d
= 5EEE
h
Moment of inertia for setpoint feedforward control at sensorless vector control (
)
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
kg cm^2
600000.00 0.00 kg cm^2
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00275 | Filter setpoint feedforward control
Data type: UNSIGNED_16
Index: 24300
d
= 5EEC
h
Filter time of the setpoint feedforward control at sensorless vector control (
• The setpoint feedforward control requires the entry of the moment of inertia in
.
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
ms
1000.0 1.0 ms
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10