Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

523

15

Parameter reference

15.2

Parameter list | C00246

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00246

C00247

C00249

C00265

C00273

C00275

Parameter | Name:

C00246 | L_PCTRL_1: nAct_a internal

Data type: INTEGER_16

Index: 24329

d

= 5F09

h

FB

L_PCTRL_1

: Display of the internal actual value

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00247 | L_PCTRL_1: ActEqSet window

Data type: INTEGER_16

Index: 24328

d

= 5F08

h

From version 06.00.00

FB

L_PCTRL_1

: Window for comparison operation "actual value = setpoint"

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 2.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00249 | L_PT1_1: Time constant

Data type: UNSIGNED_16

Index: 24326

d

= 5F06

h

FB

L_PT1_1

: Time constant Tn

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

5000 2000 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00265 | SLVC: Tn torque controller

Data type: UNSIGNED_8

Index: 24310

d

= 5EF6

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00273 | Moment of inertia

Data type: UNSIGNED_32

Index: 24302

d

= 5EEE

h

Moment of inertia for setpoint feedforward control at sensorless vector control (

SLVC

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

kg cm^2

600000.00 0.00 kg cm^2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00275 | Filter setpoint feedforward control

Data type: UNSIGNED_16

Index: 24300

d

= 5EEC

h

Filter time of the setpoint feedforward control at sensorless vector control (

SLVC

)

• The setpoint feedforward control requires the entry of the moment of inertia in

C00273

.

Setting range

(min. value | unit | max. value)

Lenze setting

0.0

ms

1000.0 1.0 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10