C00003

C00005

C00002/32

0: Off / ready

Check password

From version 06.00.00

Password protection

C00002/33

0: Off / ready

Delete password

From version 06.00.00

Password protection

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00002 | Device command

Data type: UNSIGNED_8

Index: 24573

d

= 5FFD

h

Parameter | Name:

C00003 | Status of last device command

Data type: UNSIGNED_8

Index: 24572

d

= 5FFC

h

Status of the device command executed last (

C00002

).

Note:

Before switching off the supply voltage after carrying out a device command, check whether the device command

has been carried out successfully via the status display!

Drive control (DCTRL)

:

Device commands

Selection list

(read only)

Info

0 Successful

Device command has been executed successfully.

1 Command unknown

Device command implausible or unknown to the system.

2 Password protection

Unauthorised access for requested device command.

3 Time-out

Device command could not be processed in the defined

time (timeout).

4 System fault
5 Command server assigned
6 Controller inhibit required

10 Memory module binding error
11 Password too short
12 Wrong password
13 Password already set
14 Password not assigned

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00005 | Application

Data type: UNSIGNED_16

Index: 24570

d

= 5FFA

h

Selection of the technology application
Selection list

(Lenze setting printed in bold)

Info

0 Wiring has changed

This display appears if the FB interconnection has been

changed in the application level using the FB Editor.

1000 Actuating drive speed

This technology application is used to solve speed-

controlled drive tasks, e.g. conveying belts.

3000 Switch-off positioning

This technology application is used to solve speed-

controlled drive tasks which require a pre-switch off or

stopping at certain positions, e.g. roller conveyors and

conveying belts. This is implemented by connecting

switch-off sensors.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT