21 l_muldiv_1, L_muldiv, L_muldiv_1 – Lenze E84DSxxx User Manual
Page 745: 17 function library

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
745
17
Function library
17.1
Function blocks | L_MulDiv_1
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.21
L_MulDiv_1
This FB multiplies the analog input signal with a parameterisable factor.
• The value of the factor is determined by a quotient consisting of numerator and denominator .
• The value output at nOut_a is limited to ±199.99 %.
• Division is not remainder considered.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
nIn1
INT
Input signal
Identifier
Data type
Value/meaning
nOut_a
INT
Product value (result of the multiplication)
• Internal limitation to ± 32767
Parameter
Possible settings
Info
-32767
32767 Counter
-32767
32767 Denominator
/B0XO'LYB
Q,QBD
Q2XWBD
&
&
nOut_a
nIn_a C00699/1
C00699/2
-------------------------
Ч
=