background image

16

Working with the FB Editor

16.2

User interface

670

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

"Free interconnection" level
This level serves to implement an individual drive solution for the "HighLine" version.

16.2.4

Editor view/overview

Use the list field at the top right to change from the Editor to the overview and vice versa.
The overview shows all function blocks used of the interconnection in the upper list field in the order

of their processing. The lower list field shows all used system blocks.

• The processing order of the function blocks can be optimised manually or according to an

automatically generated selection.

Changing the processing order

( 697)

Note!

When you select the "Free interconnection" level for the first time, you are prompted to

confirm whether the interconnection from the I/O level and the application level are to

be combined and copied into this level.
When you confirm this confirmation prompt with Yes, the I/O level and the application

level are not available anymore. This action can only be undone by resetting the

application to a predefined Lenze application!

Resetting changed interconnection

( 702)