1 main setpoint path, Main setpoint path, 17 function library – Lenze E84DSxxx User Manual

Page 752

Advertising
background image

17

Function library

17.1

Function blocks | L_NSet_1

752

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

17.1.26.1 Main setpoint path

• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal

conditioning operates with the JOG value.

C00221

0.000

s

999.900 Deceleration time T

if

for the

additional setpoint

• Lenze setting: 0.000 s

C00241

0.00

%

100.00 Hysteresis window for zero detection

of speed output setpoint (output

bRfgIEqO)

• Lenze setting: 0.50 %

C00632/1...3

0.00

%

199.99 Maximum limit values for the speed

blocking zones

• Selection of the maximum limit

values for the blocking zones in

which the speed must not be

constant.

• Lenze setting: 0.00 %

C00633/1...3

0.00

%

199.99 Minimum limit values for the speed

blocking zones

• Selection of the minimum limit

values for the blocking zones in

which the speed must not be

constant.

• Lenze setting: 0.00 %

C00634

Status (bit-coded)

• Bits that are not listed are

reserved for future extensions.

Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active

C00635

-199.99

%

199.99 nMaxLimit

• Maximum speed setpoint for

speed setpoint limitation

• Lenze setting: 199.99 %

C00636

-199.99

%

199.99 nMinLimit

• Minimum speed setpoint for

speed setpoint limitation

• Lenze setting: -199.99 %

Parameter

Possible settings

Info