Function blocks | L_NSet_1
752
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.26.1 Main setpoint path
• The signals in the main setpoint path are limited to a value range of ±32767.
• The signal at nNSet_a is first led via the JOG selection function.
• A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal
conditioning operates with the JOG value.
0.000
s
999.900 Deceleration time T
if
for the
additional setpoint
• Lenze setting: 0.000 s
0.00
%
100.00 Hysteresis window for zero detection
of speed output setpoint (output
bRfgIEqO)
• Lenze setting: 0.50 %
0.00
%
199.99 Maximum limit values for the speed
blocking zones
• Selection of the maximum limit
values for the blocking zones in
which the speed must not be
constant.
• Lenze setting: 0.00 %
0.00
%
199.99 Minimum limit values for the speed
blocking zones
• Selection of the minimum limit
values for the blocking zones in
which the speed must not be
constant.
• Lenze setting: 0.00 %
Status (bit-coded)
• Bits that are not listed are
reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active
-199.99
%
199.99 nMaxLimit
• Maximum speed setpoint for
speed setpoint limitation
• Lenze setting: 199.99 %
-199.99
%
199.99 nMinLimit
• Minimum speed setpoint for
speed setpoint limitation
• Lenze setting: -199.99 %
Parameter
Possible settings
Info