5 setting parameters (short overview), Setting parameters (short overview), 7technology applications – Lenze E84DSxxx User Manual
Page 285

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
285
7
Technology applications
7.3
TA "Switch-off positioning"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.5
Setting parameters (short overview)
Bit 13 Trouble
1 ≡ Controller is in the "
" device status
• E.g. if an overvoltage has occurred.
Bit 14 JogCtrlInputSel1
Binary coded selection of the switch-off position 1 ... 3
• Bit 5 and bit 6 of the control word.
Bit 15 JogCtrlInputSel2
Status word
Name
Status
Parameter
Info
Lenze setting
Value Unit
Appl.: Reference speed
1500 rpm
Accel. time - main setpoint
2.000 s
Decel. time - main setpoint
2.000 s
Decel. time - quick stop
2.000 s
Fixed setpoint 1
40.00 %
Fixed setpoint 2
60.00 %
Fixed setpoint 3
80.00 %
Fixed setpoint 4 ... 15
0.00 %
Add. accel. time 1 ... 15
0.000 s
Add. decel. time 1 ... 15
0.000 s
Decel. time - quick stop
2.000 s
Auto-DCB: Hold time
0.500 s
DCB: Hold time
999.000 s
Ramp smoothing main setpoint
0: Off
S-ramp time PT1
20.00 s
Setpoint arithmetic
0: NOut = NSet
Accel. time - add. setpoint
0.000 s
Decel. time - add. setpoint
0.000 s
L_NSet_1: Hyst. NSet reached
0.50 %
InputSens.SlowDown1
0: Level
InputSens.Stop1
0: Level
InputSens.SlowDown2
0: Level
InputSens.Stop2
0: Level
InputSens.SlowDown3
0: Level
InputSens.Stop3
0: Level
L_NSet_1: Blocking speed 1 max
0.00 %
L_NSet_1: Blocking speed 2 max
0.00 %
L_NSet_1: Blocking speed 3 max
0.00 %
L_NSet_1: Blocking speed 1 min
0.00 %
L_NSet_1: Blocking speed 2 min
0.00 %
L_NSet_1: Blocking speed 3 min
0.00 %
L_NSet_1: nMaxLimit
199.99 %
L_NSet_1: nMinLimit
-199.99 %
L_OffsetGainP_1: Gain
1.0000
L_OffsetGainP_2: Gain
1.0000