C00190 | setpoint arithmetic, C00199 | description data, C00200 | firmware product type – Lenze E84DSxxx User Manual
Page 517: C00201 | firmware, C00200, C00190, Nadd" in, To "1, C00201/1, 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
517
15
Parameter reference
15.2
Parameter list | C00190
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00190
C00199
C00200
C00201
Parameter | Name:
C00190 | Setpoint arithmetic
Data type: UNSIGNED_8
Index: 24385
d
= 5F41
h
FB: Selection of arithmetics
• To be able to influence the main setpoint (NSet) by an additional setpoint (NAdd).
Selection list
(Lenze setting printed in bold)
0 Out = Set
1 Out = Set + Add
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 Out = (Set*100%)/(100%-Add)
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00199 | Description data
Data type: VISIBLE_STRING
Index: 24376
d
= 5F38
h
From version 06.00.00
Parameters for storing decription data for the controller
Subcodes
Lenze setting
Info
C00199/1
Device name
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
Display of the firmware product type
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00201 | Firmware
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
Display of the firmware data of the control card and the power section
Subcodes
Info
C00201/1
Firmware type - ctrl card
C00201/2
Firmware version - ctrl card
C00201/3
Firmware comp. file - ctrl card
C00201/4
Firmware type - power section
C00201/5
Firmware version - power sect.
C00201/6
Firmw. comp. file - power sect.
Read access Write access CINH PLC STOP No transfer COM MOT