Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

367

9

Diagnostics & error management

9.10

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PS10: Memory module binding invalid [xx.0144.00010]

dF14: SW-HW invalid [xx.0145.00014]

dF18: BU RCOM error [xx.0145.00024]

dF25: CU RCOM error [xx.0145.00025]

dF21: BU watchdog [xx.0145.00033]

dF22: CU watchdog [xx.0145.00034]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device personalisation is active: The binding ID of the

memory module does not comply with the binding ID of

the controller.

• Use memory module/controller with matching

binding IDs.

• Contact machine manufacturer.

Note:

It is not possible for Lenze to modify a replacement

device via special accesses in such a way that it

cooperates with a personalised memory module.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Mains switching too frequent.

• Cyclic mains switching every 3 min is permissible.

• After switching the mains 3 times in one minute,

there must be a switching pause of 9 min.

• Please contact Lenze if the problem occurs again.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Device error

Consultation with Lenze required.