4 drive diagnostics with the »engineer, Drive diagnostics with the »engineer, 9diagnostics & error management – Lenze E84DSxxx User Manual
Page 329

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
329
9
Diagnostics & error management
9.4
Drive diagnostics with the »Engineer«
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.4
Drive diagnostics with the »Engineer«
When an online connection to the controller has been established, the connected controller can be
diagnosed and relevant actual controller states can be displayed in a clearly arranged visualisation
using the »Engineer«:
Button
Function
Display details of the status determining error.
Display details of the current error.
Display all active sources of a controller inhibit.
Display all active sources of a quick stop.
Reset error
Acknowledge error message (if the error cause has been eliminated).
Logbook...
Display the Logbook
of the controller.
Monitoring...
Configure the Monitoring
Device status...
Display the internal state machine including the current device status.
Drive control...
Display the bit assignment of the following control-related words:
• MCI control word (
• CAN control word (
)
• Cause of controller inhibit (
)
• Cause of quick stop (
)
• Status word (
)
• Status word 2 (
Device information...
Display identification data, e.g. firmware information or serial number of individual
controller components.