1 operating mode, Operating mode, 8basic drive functions (mck) – Lenze E84DSxxx User Manual

Page 309

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

309

8

Basic drive functions (MCK)

8.4

Holding brake control

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Short overview of parameters for holding brake control:

8.4.2.1

Operating mode

For different applications and tasks, different operating modes are available in

C02580

. The

selected operating mode determines whether the holding brake control is used and how the

holding brake will be switched.

Mode 0: Brake control off
In this mode, brake control is switched off (not active).

• The bBrkReleaseOut trigger signal for the holding brake control switching element is set to

FALSE.

• The bBrkReleased status signal is set to FALSE.

Parameter

Info

Lenze setting

Value Unit

C02580

Holding brake: Operating mode

12: Autom. controlled

C02581/1

Holding brake: Switching threshold

5.00 %

C02581/2

Holding brake: Hyst. release

1.00 %

C02581/3

Holding brake: Hyst. close

1.00 %

C02582

Holding brake: Setting

0

C02589/1

Holding brake: Closing time

100 ms

C02589/2

Holding brake: Release time

100 ms

C02589/3

In preparation - without function at the moment!

Holding brake: Waiting time status

100 ms

C02593/1

Holding brake: Actual value monitoring

0.000 ms

C02610/1

MCK: Holding brake ramp time synchr.

2.000 s

C02607

Holding brake: Status

-

C00830/68

MCK: nBrkAddValue_a

- %

C00833/80

MCK: bBrkRelease

-

C00833/81

MCK: bBrkStartValue2

-

C00833/82

MCK: bBrkApplied

-

Highlighted in grey = display parameter

Advertising