1 operating mode, Operating mode, 8basic drive functions (mck) – Lenze E84DSxxx User Manual
Page 309

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
309
8
Basic drive functions (MCK)
8.4
Holding brake control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Short overview of parameters for holding brake control:
8.4.2.1
Operating mode
For different applications and tasks, different operating modes are available in
selected operating mode determines whether the holding brake control is used and how the
holding brake will be switched.
Mode 0: Brake control off
In this mode, brake control is switched off (not active).
• The bBrkReleaseOut trigger signal for the holding brake control switching element is set to
FALSE.
• The bBrkReleased status signal is set to FALSE.
Parameter
Info
Lenze setting
Value Unit
Holding brake: Operating mode
12: Autom. controlled
Holding brake: Switching threshold
5.00 %
Holding brake: Hyst. release
1.00 %
Holding brake: Hyst. close
1.00 %
Holding brake: Setting
0
Holding brake: Closing time
100 ms
Holding brake: Release time
100 ms
In preparation - without function at the moment!
Holding brake: Waiting time status
100 ms
Holding brake: Actual value monitoring
0.000 ms
MCK: Holding brake ramp time synchr.
2.000 s
Holding brake: Status
-
MCK: nBrkAddValue_a
- %
MCK: bBrkRelease
-
MCK: bBrkStartValue2
-
MCK: bBrkApplied
-
Highlighted in grey = display parameter