5

Motor control (MCTRL)

5.7

Parameterisable additional functions

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.7.5

Oscillation damping

Mechanical oscillations are undesirable effects in every process and they may have an adverse effect

on the single system components and/or the production output.
Mechanical oscillations in the form of speed oscillations are suppressed by the oscillation damping

function.
Mechanical oscillations may occur:

• In the voltage range (output voltage is lower than max. voltage)

• Here, the oscillations occur in no-load operation.
• Here, speeds of 40 ... 80 % of the rated speed are typical.
• See subchapter "

Oscillation damping voltage range

".

( 162)

• In the field weakening range (output voltage has reached maximum voltage)

• Here, the oscillations occur in no-load operation and with load.
• Here, speeds higher than the rated speed are typical, especially when the output frequency is

close to the mains frequency.

• See subchapter "

Oscillation damping in the field weakening range

".

( 163)