Ps03: par. set device invalid [xx.0144.00003, Ps04: par. set mci invalid [xx.0144.00004, Ps07: par. memory module invalid [xx.0144.00007 – Lenze E84DSxxx User Manual

Page 366: Ps08: par. device invalid [xx.0144.00008, Ps09: par. format invalid [xx.0144.00009, Ps03: par.set device invalid, Xx.0144.00003, Xx.0144.00004, Xx.0144.00007, Xx.0144.00008

Advertising
background image

9

Diagnostics & error management

9.10

Error messages of the operating system

366

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

PS03: Par. set device invalid [xx.0144.00003]

PS04: Par. set Mci invalid [xx.0144.00004]

PS07: Par. memory module invalid [xx.0144.00007]

PS08: Par. device invalid [xx.0144.00008]

PS09: Par. format invalid [xx.0144.00009]

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set saved to the memory module is

incompatible to the standard device.

• An incompatibility of the parameter set is caused e.g.

when the memory module of an 8400 HighLine is

plugged into an 8400 StateLine or the parameter set

in the memory module has a higher version than

expected by the standard device.

When the memory modules are exchanged, observe the

downward compatibility:

• OK: StateLine V2.0 to StateLine V3.0

• OK: StateLine V2.0 to HighLine V2.0

• Not OK: HighLine Vx.x to StateLine Vx.x

• Not OK: StateLine V3.0 to StateLine < V3.0

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set saved to the communication module

is incompatible to the standard device.

• An incompatibility of the parameter set is caused e.g.

when the MCI module parameters in the memory

module do not match the plugged communication

module.

When the memory modules are exchanged, observe the

downward compatibility:

• OK: StateLine V2.0 to StateLine V3.0

• OK: StateLine V2.0 to HighLine V2.0

• Not OK: HighLine Vx.x to StateLine Vx.x

• Not OK: StateLine V3.0 to StateLine < V3.0

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set saved to the memory module is

invalid.

• The error occurs while loading the parameter set.

• The memory module plugged in the device lacks a

code or a code is incorrect.

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The parameter set in the device is invalid.

• The error occurs while loading the parameter set.

• One code in the device is incorrect.

Consultation with Lenze required.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The code format is invalid.

• The error occurs while loading the parameter set.

Consultation with Lenze required.