6 enable controller and test application, Enable controller and test application, 3commissioning – Lenze E84DSxxx User Manual

Page 52: Stop

Advertising
background image

3

Commissioning

3.7

Commissioning of the "Actuating drive speed" technology application

52

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

3.7.5

Saving parameter settings safe against mains failure

The parameter set must be saved to the device safe against mains failure to prevent parameter

settings becoming lost due to mains switching.

•

Save parameter set.

3.7.6

Enable controller and test application

1.

Enable controller.

• If there is no other active source for the controller inhibit, the controller changes from the

"

SwitchedOn

" status to the "

OperationEnabled

" status.

• The Diagnostics tab and

C00158

display all active sources for the controller inhibit.

2. Select the speed setpoint.

• In the "Terminal 0" control mode by selecting a voltage at the analog input via the setpoint

potentiometer or by selecting a fixed setpoint via the digital DI1/DI2 inputs:

Tip!
Other control functions in the "Terminal 0" control mode:

• DI3: HIGH level ≡ Request DC-injection braking
• DI4: HIGH level ≡ Request a change of direction of rotation

Stop!

Before stipulating a speed setpoint, check whether the brake in the form of a holding

brake on the motor shaft has been released!

DI1

DI2

Speed selection

LOW

LOW

The setpoint speed is selected via analog input 1

• Scaling: 10 V ≡ 100 % ≡ reference speed (

C00011

)

HIGH

LOW

Fixed setpoint 1 (

C00039/1

) is used as setpoint speed.

• Lenze setting: 40 % of the reference speed (

C00011

)

LOW

HIGH

Fixed setpoint 2 (

C00039/2

) is used as setpoint speed.

• Lenze setting: 60 % of the reference speed (

C00011

)

HIGH

HIGH

Fixed setpoint 3 (

C00039/3

) is used as setpoint speed.

• Lenze setting: 80 % of the reference speed (

C00011

)

Note!

Observe the actual speed value (display in

C00051

) as well as the

LED status displays

.

( 323)

Advertising