C00634 | l_nset_1: wstate, C00635 | l_nset_1: nmaxlimit, C00636 | l_nset_1: nminlimit – Lenze E84DSxxx User Manual
Page 579: C00635, C00636, 15 parameter reference

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
579
15
Parameter reference
15.2
Parameter list | C00634
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00634
C00635
C00636
Parameter | Name:
C00634 | L_NSet_1: wState
Data type: UNSIGNED_16
Index: 23941
d
= 5D85
h
FB: Bit coded status display
Display area
(min. hex value | max. hex value)
0x0000
0xFFFF
Value is bit-coded:
Info
Bit 0 No blocking zone active
"1" ≡ No blocking zone set for constant speeds
Bit 1 Blocking zone 1 active
"1" ≡ Suppression of constant speed characteristics
within the limits of blocking zone 1
Bit 2 Blocking zone 2 active
"1" ≡ Suppression of constant speed characteristics
within the limits of blocking zone 2
Bit 3 Blocking zone 3 active
"1" ≡ Suppression of constant speed characteristics
within the limits of blocking zone 3
Bit 4 Jog in blocking zone
"1" ≡ A ramp is used to keep the speed setpoint within a
speed blocking zone
Bit 5 MaxLimit active
"1" ≡ Speed setpoint is at the maximum speed limit
Bit 6 MinLimit active
"1" ≡ Speed setpoint is at the minimum speed limit
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00635 | L_NSet_1: nMaxLimit
Data type: INTEGER_16
Index: 23940
d
= 5D84
h
FB: Maximum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 199.99 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00636 | L_NSet_1: nMinLimit
Data type: INTEGER_16
Index: 23939
d
= 5D83
h
FB: Minimum speed setpoint for speed setpoint limitation
Setting range
(min. value | unit | max. value)
Lenze setting
-199.99
%
199.99 -199.99 %
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100