14

Parameter change-over

14.2

Configuring the list using the »Engineer« parameterisation dialog

460

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Outputs

14.2

Configuring the list using the »Engineer« parameterisation dialog

Proceed as follows to open the dialog for parameterising the parameter change-over:

1. »Engineer« Go to the Project view and select the 8400 protec StateLine controller.
2. Select the Application parameters tab from the Workspace.
3. Go to the Overview dialog level and click the "basic functions" button.
4. Go to the OverviewBasic functions dialog box and click the Parameter change-over

button.

Identifier

Data type

Value/meaning

bDone

BOOL

"Writing of the parameter list completed" status signal

• The output is automatically reset to FALSE if writing via bExecute is activated

again.

TRUE Writing of the parameter list successfully completed.

FALSE The FALSE status can have the following meanings:

1.There is no active writing of the parameter list.

2.Writing of the parameter list has not been completed yet.

3.An error has occurred (if bFail = TRUE).

bFail

BOOL

"Error" status

TRUE An error has occurred (group signal).

• For details see display parameter

C01083

.