C00916 | motor cable cross-section, C00917 | motor cable resistance, C00950 | l_interpolator_1: activation fb functions – Lenze E84DSxxx User Manual
Page 618: C00916, Motor c, C00917, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C00916
618
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00916
C00917
C00922
C00950
C00951
Parameter | Name:
C00916 | Motor cable cross-section
Data type: UNSIGNED_16
Index: 23659
d
= 5C6B
h
Motor cable cross-section of a phase/cable for calculating the motor cable resistance
• The calculated motor cable resistance is displayed in
Setting range
(min. value | unit | max. value)
Lenze setting
0.50
mm^2
100.00 6.00 mm^2
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 100
Parameter | Name:
C00917 | Motor cable resistance
Data type: UNSIGNED_16
Index: 23658
d
= 5C6A
h
Display of the motor cable resistance of a motor cable phase
• The motor cable resistance is calculated from the motor cable length set in
and the motor cable cross-
Display range
(min. value | unit | max. value)
0
mOhm
64000
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00922 | ICM_DiagnosticCounter
Data type: UNSIGNED_16
Index: 23653
d
= 5C65
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00950 | L_Interpolator_1: Activation FB functions
Data type: UNSIGNED_8
Index: 23625
d
= 5C49
h
FB: Activation of signal interpolation and signal monitoring
Selection list
0 Off
1 On
Subcodes
Lenze setting
Info
C00950/1
0: Off
Activation of signal interpolation
C00950/2
0: Off
Activation of signal monitoring
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00951 | L_Interpolator_1: No. of interpolation steps
Data type: UNSIGNED_16
Index: 23624
d
= 5C48
h
FB: No. of interpolation steps
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 1
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1