C00606 | resp. to motor overload (i·xt), C00607 | resp. to max freq. feedb. dig12/56, C00608 | resp. to maximum torque – Lenze E84DSxxx User Manual

Page 569: C00609 | resp. to maximum current, C00606, C00609, C00608, Set in, Onse set in, C00607

Advertising
background image

Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05

569

15

Parameter reference

15.2

Parameter list | C00606

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00606

C00607

C00608

C00609

C00610

Parameter | Name:

C00606 | Resp. to motor overload (I²xt)

Data type: UNSIGNED_8

Index: 23969

d

= 5DA1

h

Response if the adjustable motor overload threshold (

C00120

) is reached.

• The current thermal motor load is displayed in

C00066

.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00607 | Resp. to max freq. feedb. DIG12/56

Data type: UNSIGNED_8

Index: 23968

d

= 5DA0

h

Response when the maximum input frequency has been reached via the digital inputs.
Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00608 | Resp. to maximum torque

Data type: UNSIGNED_8

Index: 23967

d

= 5D9F

h

Response if the maximum torque (

C00057

) is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00609 | Resp. to maximum current

Data type: UNSIGNED_8

Index: 23966

d

= 5D9E

h

Response if the maximum current (

C00022

,

C00023

) is reached.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00610 | 16-bit connection table

Data type: UNSIGNED_16

Index: 23965

d

= 5D9D

h

This code is for device-internal use only and must not be written to by the user!

Advertising