2 terminals 2, Terminals 2, Control mode – Lenze E84DSxxx User Manual
Page 276: 7technology applications

7
Technology applications
7.3
TA "Switch-off positioning"
276
Lenze · 8400 protec StateLine · Reference manual · DMS 4.2 EN · 03/2013 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.3.3.2
Terminals 2
Connection
Assignment
Connection
Assignment
X41/DI1
LA_SwitchPos: bJogCtrlStop1
DO1/DO2 is only available after respective change of the function
X41/DI2
LA_SwitchPos: bJogCtrlStop2
X42/DI3
LA_SwitchPos: bRLQCw
LA_SwitchPos: bJogCtrlInputSel1
X42/DO1
-
X42/DI4
LA_SwitchPos: bRLQCcw
LA_SwitchPos: bJogCtrlInputSel2
X42/DO2
LA_SwitchPos.bDriveReady
X43/DI5
-
X50/A1U
LA_SwitchPos.nMainSetValue_a
10 V ≡ 100 % reference speed (
X43/DI6
-
DI3
/DO1
DI4
/DO2
X50
GIO
GIO
GIO
DI1
DI5
n.c.
n.c.
n.c.
DI2
DI6
AR
A1U
GA
A1I
24O
+
X41
X42
X43
24O
24O
24O
+
+
+
+ 24 V
RFR
R
1k
... 10k
W
W
Stop function 1
Stop function 2
CW rotation quick stop /
selection of switch-off position 1
CCW rotation quick stop /
selection of switch-off position 2
Controller enable
Speed setpoint