C00637

C00638

C00639

C00640

C00670

Parameter | Name:

C00637 | L_NSet_1: Output blocking zones

Data type: INTEGER_16

Index: 23938

d

= 5D82

h

The

L_NSet_1

FB: Speed setpoint is displayed after being processed by blocking zone function

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00638 | L_NSet_1: Output ramp rounding

Data type: INTEGER_16

Index: 23937

d

= 5D81

h

The

L_NSet_1

FB: Speed setpoint is displayed after being processed by PT1 filter function

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00639 | L_NSet_1: Output additional value

Data type: INTEGER_16

Index: 23936

d

= 5D80

h

The

L_NSet_1

FB: Additional speed setpoint is displayed after being processed by the ramp generator

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00640 | L_NSet_1: nNOut_a

Data type: INTEGER_16

Index: 23935

d

= 5D7F

h

The

L_NSet_1

FB: Display of the generated main speed setpoint at the output nNOut_a

Display range

(min. value | unit | max. value)

-199.99

%

199.99

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00670 | L_OffsetGainP_1: Gain

Data type: INTEGER_32

Index: 23905

d

= 5D61

h

The

L_OffsetGainP_1

FB: Gain as multiplier of the input signal + offset

Setting range

(min. value | unit | max. value)

Lenze setting

-100.0000

100.0000 1.0000

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000