3.2 Basic Module Connections

3.2.3 MECHATROLINK Connectors

3-14

( 2 ) Connection Procedure

The power supply terminal has a removable connector. Use the following procedure to wire the terminal to the power
supply connector. Use 0.2 mm

2

to 0.51 mm

2

(AWG24 to AWG20) twisted-pair cable.

1.

Strip approx. 6.5 mm the end of the wire.

2.

Open the wire insert opening on the terminal with the tool shown in Fig. A or Fig. B.

3.

Insert the wire into the opening and then close the opening by releasing the lever or removing the
screwdriver.

3.2.3 MECHATROLINK Connectors

MECHATROLINK connector is used to connect the MP2300S and the SERVOPACKs and distributed I/O via
MECHATROLINK cables.

( 1 ) Specifications and Pin Arrangement

Fig. A (with lever)

Fig. B (with screwdriver)

8 to 9 mm

Name

Connector

Name

No. of

Pins

Connector Model

Module

Cable

Manufacturer

MECHATROLINK
Connector

M-I/II

8

1903815-1

2040305-1

Tyco Electronics
Japan G.K.

No.

Signal Name

Description

No.

Signal Name

Description

A1

B1

A2

SRD

Signal

B2

SRD

Signal

A3

SRD+

Signal +

B3

SRD+

Signal +

A4

SLD

Shield

B4

SLD

Shield

M-I/II