Appendix b servopack parameter data flow, B.1 operations and parameter data flow, A-20 – Yaskawa MP2300S Basic Module User Manual

Page 342: 1 ) power on

Advertising
background image

Appendix B SERVOPACK Parameter Data Flow

B.1 Operations and Parameter Data Flow

A-20

Appendix B SERVOPACK Parameter Data Flow

In systems connected to MECHATROLINK, SERVOPACK parameters can be read directly from the MP2300S. (Refer
to 11.6 Parameters That Are Automatically Updated in Machine Controller MP2000-series SVB/SVB-01 Motion Mod-
ule User’s Manual
(manual number: SIEP C880700 33). This means that parameters are saved in the memory area of
both the MP2300S and the SERVOPACK. It is thus necessary to consider the relationship between the settings in both
memory areas.

B.1

Operations and Parameter Data Flow

( 1 ) Power ON

1.

Parameter data saved in the SERVOPACK’s EEPROM

*1

is copied to SERVOPACK’s RAM

*2

.

2.

Parameter data saved in the MP2300S’s flash memory

*1

for all axes is copied to SDRAM

*2

.

Some gain-related settings are sent from the MP2300S to SERVOPACK RAM.

* 1. EEPROM, flash memory, and SRAM: Store data even when the power is turned OFF.
* 2. RAM (SRAM, SDRAM): Lose data when the power is turned OFF.

Œ

Indicates data has been written (same below).

RAM

EEP

-ROM

SDRAM

MECHATROLINK

SRAM

Input

Data

MPE720

HDD in personal computer

Flash

Memory

Servo Parameters

(All Axes)

Parameters

System

Software

Control

Software

MP2300S

SERVOPACK

SERVOPACK

Send Send

Advertising