3 ) work register – Yaskawa MP2300S Basic Module User Manual

Page 162

Advertising
background image

5.2 User Programs

5.2.3 Sequence Program

5-29

Outline of Motion Control Systems

( 3 ) Work Register

Monitor a sequence program through a work register.
A work register, similar to the motion program registered in M-EXECUTOR, has status flags in the M-EXECUTOR
control register.
The following table shows the work register configuration of the sequence program.

[ a ] Status Flag of Sequence Program

The status flags of a sequence program allow you to know the execution status of the sequence program.
The following table explains the detailed contents of status flags.
[Status]

„

Sequence program alarm

When referencing a sub sequence program (SSEE command execution) and an error is detected, “Bit8: Program alarm is occur-
ring” is turned ON. If the error is cleared, it is turned OFF.
Error details are as follows:

Work Register

Content

Status

Status flag of a sequence program

Table 5.3 Status

Bit No.

Status

0

Program running

1

(Reserved)

2

(Reserved)

3

(Reserved)

4

(Reserved)

5

(Reserved)

6

(Reserved)

7

(Reserved)

8

Program alarm is occurring

9

Stopping at breakpoint

A

(reserved)

B

In debug mode (EWS debug operation)

C

Program type 1: Sequence program

D

Start request history

E

(Reserved)

F

(Reserved)

Error Details

Called program is unregistered
Called program is not a sequence program
Called program is not a sub program (main program is called)
Called program number is over
Nest over error