Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1 Message Transmit Function (MSG-SND)

A-80

( d ) PARAMETER (parameter)

When RESULT (process result) = 4 (FMT_NG: parameter format error), an error code in the table below is output.
Otherwise, the connection number is output.

( 4 ) Connection Number (PARAM02)

Refer to G.1.4 ( 4 ) Connection Number (PARAM02).

( 5 ) Data Address (PARAM05)

Specify the start address of the data.
The address must be input in a decimal or hexadecimal number.
Example: When the start address is MW01000, specify “1000 (decimal)” or “3E8H (hexadecimal).”
The following table provides the valid ranges of the data addresses.

* The unit for address setting is word address.

RESULT (process result)

Code (Hex)

Meaning

When RESULT
(process result) = 4
(FMT_NG: parameter format
error)

00

No error

01

Connection number is out of range

02

Time error while monitoring to receive MEMOBUS response
(for MEMOBUS protocol)

03

Error in setting retransmit count

04

Error in setting cyclic area

05

CPU number error

06

Data address error

07

Data size error

08

Function code error (for MEMOBUS protocol)

Others

xx

Connection number

Table G.17 Valid Range of Data Addresses (non-procedure)

Non-procedural

Type

Target Data

Type

Function

Valid Range of Data Addresses

Ethernet(218IF)

Ethernet(218IFA)

Non-procedure 1

W

Transmits data in words

0 to 65534 (0 to FFFEH)

Non-procedure 2

B

Transmits data in bytes

*

0 to 65534 (0 to FFFEH)