Yaskawa MP2300S Basic Module User Manual

Page 200

Advertising
background image

6.2 Communication with Other MP Series

6.2.1 When the MP2300S Acts as Slave (automatic receive function is used)

6-11

Built-in Ethernet Communications

4.

Create a ladder program with a message transmit function (MSG-SND).

A ladder program for transmitting messages to/from the remote equipment (MP2300) side is shown as follows:

„

Message transmit function (MSG-SND)

Required for transmitting messages. Message transmission is carried out by describing and executing this mes-
sage transmit function in a ladder program.

Fig. 6.2 MPE720 Module Configuration Definition Window

Execute

Abort

Dev-Typ

Pro-Typ

Cir-No
Ch-No

Param

MSGSND

Busy

Complete

Error

&$

&$







&#



&$

&$

&$

Communication device = Ethernet(218IF)

Protocol type

Line number = 1

Communication buffer channel number

Parameter list start address

=DA00000

Communication device = 218IF

Line number = 1

Advertising