2.2 Basic Module

2.2.4 218IFA Module (Ethernet)

2-22

„

Simple Setting Screen for Message Communication

Graphically sets connection parameters for each connection.
Basically, the same content as with message communication items in connection parameter setting can be set.

When connection parameters are not yet set and this screen is opened, the default value for each connection will be
automatically stored.

The following table provides the default values for each connection stored when the connection parameters are not yet
set and this screen is opened.

By clicking the Default Button, default values are set for each data code type according to the selected communication
protocol type.
The following table shows the default values for each data code type.

Item

Default

Connection

Number 01

Connection

Number 02

Connection

Number 03

Connection

Number 04

Local Port No.

10001

10002

10003

10004

Node IP Address

192.168.1.2

192.168.1.3

192.168.1.4

192.168.1.5

Node Port Number

10001

10002

10003

10004

Communication
Protocol Type

Extended MEMOBUS

Connect Type

TCP

Code

BIN

Communication Protocol Type

Default for Data Code Type

Extended MEMOBUS

BIN

MEMOBUS

RTU

MELSEC

BIN

Non-procedure

BIN

MODBUS/TCP

BIN