Appendix B SERVOPACK Parameter Data Flow

B.1 Operations and Parameter Data Flow

A-28

( 7 ) Saving Data to Flash Memory

The data flow for SERVOPACK parameters is as follows when saving the parameters to flash memory on the MPE720.

1.

The MP2300S writes the parameters data (Input Data) held in SDRAM to flash memory.

Œ

Save to flash memory also after having changed set data of SERVOPACK parameter.

„

Precautions When Saving SERVOPACK Parameters

Before executing a saving operation in the SERVOPACK Tab Page, except during SERVOPACK replacement, always select
Edit - Current Value - Setting Value to copy the values in Current Value to Input Data.

MECHATROLINK

RAM

EEP

-ROM

SRAM

SDRAM

Input

Data

MPE720

㧔online㧕

HDD in personal computer

Display

Current

Value

Input

Data

Flash

Memory

System

Software

Control

Software

Servo Parameters

(All Axes)

Parameters

SERVOPACK

SERVOPACK

Send

Send

MP2300S