Appendix B SERVOPACK Parameter Data Flow
B.1 Operations and Parameter Data Flow
A-28
( 7 ) Saving Data to Flash Memory
The data flow for SERVOPACK parameters is as follows when saving the parameters to flash memory on the MPE720.
1.
The MP2300S writes the parameters data (Input Data) held in SDRAM to flash memory.
Save to flash memory also after having changed set data of SERVOPACK parameter.
Precautions When Saving SERVOPACK Parameters
Before executing a saving operation in the SERVOPACK Tab Page, except during SERVOPACK replacement, always select
Edit - Current Value - Setting Value to copy the values in Current Value to Input Data.
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
Input
Data
MPE720
㧔online㧕
HDD in personal computer
Display
Current
Value
Input
Data
Flash
Memory
System
Software
Control
Software
Servo Parameters
(All Axes)
Parameters
SERVOPACK
SERVOPACK
Send
Send
MP2300S