Appendix G MSG-SND/MSG-RCV Functions (Ethernet)

G.1 Message Transmit Function (MSG-SND)

A-73

Appendices

( 4 ) Connection Number (PARAM02)

Refer to G.1.4 Function Setting and Parameter Details for MEMOBUS and Extended MEMOBUS Protocols.

( 5 ) Option (PARAM03)

Choose a unique setting for each communication device.
The following table provides the scope of the setting.

( 6 ) Function Code (PARAM04)

Set a function code to transmit.
The functions (read coil and input relay state, write to holding register, etc.) registered in the function codes are made
available by specifying the code.
The following table shows the available function codes when using MODBUS/TCP as a protocol.

Note: 1. B: Bit type, W: Integer type

2.

√: Available, –: Not available

3. Transmit and receive registers in the master operation mode are MW (MB) only.
4. In the slave operation mode, coil, holding register, input relay, and input register are MB, MW, IB, IW

respectively.

Communication Device

Valid Range

Remarks

Ethernet(218IF or 218IFA)

0 to 247, 255

Set a remote unit ID when MODBUS/TCP protocol is used.
When the transmission target is MP2000 series, specify “0.”

Table G.12 Function Code List (MODBUS/TCP)

Function

Code

Target Data

Type

Function

Communication device

Ethernet(218IF)

Ethernet(218IFA)

00H

Unused

01H

B

Reads coil state

02H

B

Reads input relay state

03H

W

Reads holding register content

04H

W

Reads input register content

05H

B

Changes single coil state

06H

W

Writes to single holding register

07H

:

Unused

0EH
0FH

B

Changes multiple coil states

10H

W

Writes to multiple holding registers

11H

:

Unused

15H

16H

W

Mask writes to holding register

17H

W

Reads/Writes multiple holding registers