Yaskawa MP2300S Basic Module User Manual

Page 65

Advertising
background image

2.2 Basic Module

2.2.5 Built-in SVB Module

2-39

Specifications and Functions

The following table lists the items shown in the Module Configuration Window.

Œ

“Possible” in the Modification line in the above table means that it is possible to change the setting of the item.
Always save the setting to the flash memory after having changed the setting.

Œ

When changing the setting, be careful not to set the register numbers overlapped with another module.

Œ

I/O Start Register and I/O End Register must be set even though the I/O Module is connected or not connected
to MECHATROLINK.

Item

Description

Modification

Slot Number

Slot number

Not possible

Module Type

Module detected in the slot

Possible

Controller Number

Fixed to 01

Not possible

Circuit Number

Module circuit number

Possible

I/O Start Register

I/O start register number of the I/O Module to be connected to MECHA-
TROLINK
(Setting range: 0000 to 7FFFh, max. 400h words per SVB Module)

Possible

I/O End Register

I/O last register number of the I/O Module to be connected to MECHA-
TROLINK
(Setting range: 0000 to 7FFFh, max. 400h words per SVB Module)

Possible

Disable Input

Input enabled (Enable)/disabled (Disable)

Possible
(Not possible
if the cell is
blank)

Disable Output

Output enabled (Enable)/disabled (Disable)

Possible
(Not possible
if the cell is
blank)

Motion Start Register

Start register number of the motion parameters
(Automatically sets according to the circuit number)

Not possible

Motion End Register

Last register number of the motion parameters
(Automatically sets according to the circuit number)

Not possible

Details

Opens the MECHATROLINK Transmission Definition Window.
(Double-click the MECHATROLINK cell to open the window.)

Status

Status of each module in online mode

Not possible